INSTALLATION OF THE DIVING CONCEPTS SNAP-ONTM DRYGLOVE KIT WITHOUT AN INNER  LATEX WRIST SEAL

 

Insert the suit connector down the arm of your drysuit and move it into your neoprene wrist seal.  Work the neoprene wrist seal onto the suit connector by pulling the neoprene wrist seal onto the suit connector a little at a time.  This step is not easy and you will need to take your time.  Secure the neoprene wrist seal to the suit connector by placing two outer glove (OG) O-Rings into the first and third groove toward the suit side of the ridge in the suit connector.
Pull the neoprene seal over the suit connector to expose the ridge of the suit connector.  Secure the suit connector to the neoprene wrist seal by adding an additional outer glove (OG) O-Ring.
The dryglove can then be connected to the suit connector ring.  You will have airflow into the glove and your hands will stay warm.